Home > Products > Sensors and Instruments > Soil Sensors > Soil Water Content and Temp Profile (TEROS 54)
Introduction to Sensor

Soil Water Content and Temp Profile (TEROS 54)

Soil Moisture Profile Probe

The TEROS 54 is a durable multi-depth soil moisture profile probe designed for accurate monitoring of soil volumetric water content and temperature at multiple depths. Its easy plug-and-play operation simplifies installation and measurement, while remote real-time data access allows you to monitor soil conditions efficiently from anywhere. Ideal for agriculture, irrigation management, environmental monitoring, and soil research. 

Specifications

Specifications

CategorySpecificationDetails
Volumetric Water ContentRangeMineral Soil Calibration: 0.00−0.70 m3/m3
NOTE: The VWC range is dependent on the media the sensor is calibrated to. A custom calibration will accommodate the necessary ranges for most substrates.
Soilless media calibration: 0.00-1.00 m3/m3
 Resolution0.001 m3/m3
 AccuracyGeneric Calibration: ±0.05 m3/m3 typical in mineral soils that have solution EC < 8 dS/m
Medium Specific Calibration: ±0.02–0.03 m3/m3 in any porous medium
Apparent Dielectric Permittivity (εα): 1–40 (soil range), ±1 (εα) (unitless)40–80, 15% of measurement
Measurement SpecificationsDielectric Measurement Frequency70 MHz
 Measurement VolumeSee comparison article
 TemperatureRange: –20 to +60 °C
Resolution: 0.03 °C
Accuracy: ±0.5 °C from –20°C to +0 °C±0.25 °C from 0°C to 60 °C
 Measurement Depths15, 30, 45, and 60 cm
Communication SpecificationsOutputDDI Serial and SDI-12 communications protocol
3-wire cable version
4-wire cable version
RS-485 Modbus RTU and tensioLINK serial communications protocol
4-wire version
 Data Logger CompatibilityMETER ZL6 and EM60 data loggers or any data acquisition system capable of 4.0- to 24.0-VDC power and serial interface with SDI-12 and/or RS-485 interface, Modbus RTU, or tensioLINK communication.
Physical SpecificationsDimensionsDiameter: (Shaft) 6.0 cm (2.36 in)
Length: 75.0 cm (29.53 in)
Width: (Head) 11.0 cm (4.33 in)
 Operating Temperature RangeMinimum: –20 °C
Maximum: +60 °C
 Cable LengthStandard: 5.0 m (stereo plug and stripped and tinned wires)75.0 m (maximum custom cable length)5.0 m (M12 connector)
NOTE: Contact Customer Support if a nonstandard cable length is needed.
 Cable DiameterStereo Plug: 4.2 ±0.2 mm (0.16 ±0.01 in) with minimum jacket of 0.8 mm (0.031 in)
M12 Plug: 5.5 ±0.2 mm (0.22 ±0.01 in) with minimum jacket of 1.0 mm (0.039 in)
 Connector Size3.50 mm (diameter)14.4 mm (diameter M12)
 Connector TypesStereo plug connector or stripped and tinned wires4-pin M12 connector or stripped and tinned wires
 Conductor GaugeStereo Plug: 22-AWG / 24-AWG ground wire
M12 Plug: 22-AWG
Electrical and Timing CharacteristicsSupply Voltage Power to GroundMinimum: 4.0 VDC
Maximum: 24.0 VDC
 Digital Input Voltage (Logic High)Minimum: 2.8 V
Typical: 3.6 V
Maximum: 5.0 V
 Digital Input Voltage (Logic Low)Minimum: –0.3 V
Typical: 0.0 V
Maximum: 0.8 V
 Digital Output Voltage (Logic High)Typical: 3.6 V
 Power Line Slew RateMinimum: 1.0 V/ms
 Current Drain (During Measurement)Minimum: 3 mA (during 500-ms measurement)
Typical: 35 mA (during 500-ms measurement)
Maximum: 50 mA (during 500-ms measurement)
 Current Drain (While Asleep)Minimum: 0.03 mA
Typical: 0.1 mA
 Power Up Time (DDI Serial)Minimum: 500 ms
Maximum: 800 ms
 Power Up Time (SDI-12)Typical: 1,000 ms
 Power Up Time (SDI-12, DDI Serial Disabled)Minimum: 500 ms
Typical: 600 ms
Maximum: 800 ms
 Measurement DurationMinimum: 500 ms (4 depths)
Maximum: 800 ms
OtherComplianceEM ISO/IEC 17050:2010 (CE Mark)
Prop 56 warning
Features

Special Features

01

Multi-Depth Soil Monitoring

Measures soil volumetric water content and temperature at multiple depths i.e 15, 30, 45 & 60 cm.
02

Accurate Moisture Measurement

Provides reliable soil moisture measurements with high accuracy across a wide range of soil and growing media.
03

Easy Plug-and-Play Operation

Designed for installation and simple integration, making soil monitoring easier and more efficient.
04

Real-Time Remote Data Access

Enables you to view soil moisture and temperature data remotely in real time for continuous monitoring.
Applications

Primary Applications

Precision Agriculture
water-system
Nursery Monitoring
Environmental Research
Water Management