Home > Products > Sensors and Instruments > Lysimeter > Deep Drainage (Drain Gauge G3 Lysimeter)
Introduction to Sensor

Deep Drainage (Drain Gauge G3 Lysimeter)

Measure Deep Drainage. Understand Water Movement

The Drain Gauge G3 Lysimeter is an easy-to-use and affordable solution for measuring deep drainage over large areas. Its completely sealed design protects the system from high water tables, while the large sampling volume provides reliable drainage measurements. An optional EC sensor also enables monitoring of solute fluxes.

Specifications

Specifications

Measurement Specifications

ParameterSpecifications
DrainageRange: 0−61 mm bottom of wick, 61−100 mm top of reservoir chambers
Resolution: 0.2 mm
Accuracy: ±1.4 mm
Water DepthRange: 0 – 10,000 mm
Resolution: 1.0 mm
Accuracy: ±0.25% of full scale at 20 °C
NOTE: Depth measurement accuracy assumes no abrupt temperature variations.
TemperatureRange: -40 to +60 °C
Resolution: 0.10 °C
Accuracy: ±1 °C
NOTE: The pressure transducer may be damaged or destroyed if frozen in ice. Remove sensor if the water temperature could drop below 0 °C (32 °F).
Bulk Electrical Conductivity (EC)Range: 0 – 120 dS/m
Resolution: 0 dS/m
Accuracy: ±0.01 dS/m or ±10%, whichever is greater
NOTE: The EC measurement is corrected to a standard temperature of 25 °C.

Communication Specifications

ParameterSpecifications
OutputDDI Serial or SDI-12 communications protocol
Data Logger CompatibilityMETER ZL6 data loggers and any data acquisition system capable of 4.0- to 15.0-VDC power and serial or SDI-12 communication

Physical Specifications

ParameterSpecifications
G3 Drain Gauge DimensionsMass: 20.0 kg (44.0 lb) with stainless steel DCT14.0 kg (31.0 lb) with PVC DCT
DCT DimensionsLength: 62.5 cm (24.6 in)
Inner Diameter: 25.4 cm (10.0 in)
Outer Diameter: 26.4 cm (10.4 in)
Width: 3.3 cm (1.3 in)
Reservoir DimensionsLength: 81.3 cm (32.0 in)
Outer Diameter: 11.5 cm (4.5 in)
Access Tube DimensionsLength: 180.0 cm (70.9 in)
Outer Diameter: 6.0 cm (2.4 in)
Material: Schedule 40 PVC
Sensor DimensionsLength: 9.0 cm (3.5 in)
Diameter: 3.4 cm (1.3 in)
Sampling Tube DimensionsLength: 3.0 m (118.1 in) standard, custom lengths available
Outer Diameter: 6.0 mm (0.24 in)Material: Polyethylene
Operating Temperature RangeMinimum: 0 °C
Maximum: 60 °C
NOTE: The pressure transducer may be damaged or destroyed if frozen in ice. Remove sensor if water temperature could drop below 0 °C (32 °F). .
Cable Length10.0 m (standard)
20.0 m
40.0 m (maximum)
Cable Diameter6 mm (0.25 in) with a minimum jacket of 0.80 mm (0.031 in)
Connector TypesStereo plug connector or stripped and tinned wires
Stereo Plug Connector Diameter6 mm (0.24 in)
Conductor Gauge20 AWG/21 AWG drain wire

Electrical and Timing Characteristics

ParameterSpecifications
Supply Voltage Power to GroundMinimum: 4.0 V
Typical: NA
Maximum: 15.0 V
Digital Input Voltage (Logic High)Minimum: 2.8 V
Typical: 3.6 V
Maximum: 5.0 V
Digital Input Voltage (Logic Low)Minimum: -0.3 V
Typical: 0.0 V
Maximum: 0.8 V
Digital Output Voltage (Logic High)Minimum: NA
Typical: 3.6 V
Maximum: NA
Power Line Slew RateMinimum: 1.0 V/ms
Typical: NA
Maximum: NA
Current Drain (During Measurement)Minimum: 0.5 mA
Typical: 4.0 mA
Maximum: 8.0 mA
Current Drain (While Asleep)Minimum: NA
Typical: 0.4 mA
Maximum: 0.0 mA
Power Up Time (DDI Serial)Minimum: 52 ms
Typical: NA
Maximum: 100 ms
Power Up Time (SDI-12)Minimum: NA
Typical: 700 ms
Maximum: 750 ms
Power Up Time (SDI-12, DDI Serial Disabled)Minimum: NA
Typical: 175 ms
Maximum: 200 ms
Measurement DurationMinimum: NA
Typical: 450 ms
Maximum: 600 ms

Other

ParameterSpecifications
ComplianceEM ISO/IEC 17050:2010 (CE Mark)
GSAView GSA details
Features

Special Features

01

Automatic Remote Sampling

It can be used with the optional AutoPump to automatically draw samples during remote deployments or periods of high drainage.
02

Optional EC Monitoring

The optional EC sensor enables monitoring of solute fluxes to help understand the movement of dissolved substances through the soil.
03

Large 6.1 cm Drainage Capacity

The 6.1 cm drainage capacity allows the system to collect large sampling volumes for dependable drainage monitoring.
04

Completely Sealed System

The completely sealed design protects the lysimeter from high water tables and supports reliable deep drainage measurements.
Applications

Primary Applications

surface water
Groundwater Protection
Agricultural Research
Environmental Monitoring
water-system