Introduction to Sensor

Compact, Digital, RS-485 Modbus Weather Sensor (ClimaVue 40)

All-in-One Weather Sensor with IEC 61724-1 Compliance

The ClimaVue™40 is a compact all-in-one weather sensor engineered for solar energy applications, including solar resource assessment and plant performance monitoring. Designed to support IEC 61724-1 compliance, it delivers accurate measurements of temperature, humidity, wind, precipitation, pressure, and lightning activity in a single, easy-to-install unit. 

Specifications

Specifications

Measurements Made Air temperature, precipitation, relative humidity, and wind direction and speed.
Measurement Scan Rate 1 s
Input Supply Voltage 9 to 15 Vdc
Operating Temperature Range -50° to +60°C
Average Current Drain @ 12 Vdc 6 mA
Communications RS-485 Modbus
Connector M12 five pin
Ingress Protection The ClimaVue 40 is intended for year-round, unattended outdoor use in meteorological and environmental monitoring applications. It tolerates continuous exposure to wind, heavy rain, dust, and solar radiation. When installed properly, the instrument housing provides environmental protection functionally equivalent to an IP65 rating, though no official certification is claimed. This device should not be subjected to high-pressure water streams, submersion in liquid, or corrosive gases.
Application of Council Directive(s)
  • 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
  • 2011/65/EU: Restrictions of Hazardous Substances Directive (RoHS2)
  • 2015/863/EU: Amending Annex II of RoHS Directive 2011/65/EU: Phthalates Restrictions (EU)
Standards to Which Conformity Is Declared
  • EN 61326-1:2013: Electrical equipment for measurement, control, and laboratory use—EMC requirements—for use in industrial locations
  • EN 63000:2018: Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances
Diameter 10 cm (4 in.) including rain gauge funnel
Height 34 cm (13.4 in.) including rain gauge funnel

Precipitation

Range 0 to 1,500 mm/h
Resolution 0.017 mm
Uncertainty ±5% of measurement (from 0 to 1,000 mm/h)

Vapor Pressure

Range 0 to 47 kPa
Resolution 0.01 kPa
Uncertainty Varies with temperature and humidity

Air Temperature

Range -50° to +60°C
Resolution 0.1°C
Sensor Uncertainty ±0.2°C at 25°C
Measurement Uncertainty ±0.6°C from -20° to +50°C

Relative Humidity

Measurement Range 0 to 100%
Resolution 0.1
Uncertainty ±3% RH typical (varies with temperature and humidity)

Barometric Pressure

Range 1 to 120 kPa
Resolution 0.01 kPa
Uncertainty ±0.05 kPa at 25°C
Equilibration < 10 ms
Long-Term Drift < 0.1 kPa/year, typical

Horizontal Wind Speed

Range 0 to 60 m/s
Resolution 0.01 m/s
Uncertainty 0.3 m/s or 6% of measurement, whichever is greater

Wind Gust

Range 0 to 60 m/s
Resolution 0.01 m/s
Uncertainty 0.3 m/s or 6% of measurement, whichever is greater

Wind Direction

Range 0° to 359°
Resolution
Uncertainty ±5°

Tilt

Range 0° to 180°
Resolution 0.1°
Uncertainty ±1°

Lightning Strike Count

Range 0 to 65,535 strikes
Resolution 1 strike
Uncertainty > 25% detection at < 10 km typical (variable with distance)

Lightning Average Distance

Range 0 to 40 km
Resolution 3 km
Uncertainty Variable
Features

Special Features

01

Rugged Industrial Design

Built to withstand harsh environmental conditions while maintaining long-term accuracy and reliability.
02

Integrated Surge Protection

IEC 61000-4-5 compliant protection against electrical surges and lightning events for system reliability.
03

Cost-Effective Solar Monitoring

Provides IEC 61724-1 compliant weather measurements in a compact all-in-one solution.
04

Accurate Precipitation Measurement

Dual-sensor precipitation technology improves rainfall detection accuracy and measurement reliability.
Applications

Primary Applications

Meteorological Monitoring
Solar Resource Assessment Stations
Environmental Monitoring System
Renewable Energy Research Projects
Related Products

Related Products

Compact, Digital, SDI-12 Weather Sensor (ClimaVue 50 G2)

The ClimaVue™50 G2 is a next-generation all-in-one weather sensor that delivers accurate measurements of temperature, humidity, wind, precipitation……

Compact Weather Sensor (MetSens200) 

The MetSens200 is a compact ultrasonic weather sensor that measures wind speed and direction. Its built-in electronic compass enables accurate relative wind……

Compact Weather Sensor (MetSens300) 

The MetSens300 is a compact weather sensor that measures air temperature, relative humidity, and barometric pressure within a single integrated unit. Housed in……

Compact Weather Sensor (MetSens500)

The MetSens500 is a compact all-in-one weather sensor that measures wind speed, wind direction, air temperature, relative humidity, and barometric pressure……

Compact Weather Sensor (MetSens550)

The MetSens550 is a compact all-in-one weather sensor that measures wind speed, wind direction, air temperature, relative humidity, and barometric pressure……