TEROS 06

Soil Temperature Profile Probe 

The TEROS 06 is an ultra-robust, research-grade soil temperature profile probe designed to deliver accurate temperature measurements at six different soil depths. With high accuracy and easy integration with the ZL6 data logger and ZENTRA Cloud, it provides reliable data for environmental monitoring, modeling, and research applications.

Specifications

Specifications

Measurement Specifications

ParameterSpecification
Measurement Depths5 cm, 10 cm, 20 cm, 30 cm, 50 cm, 100 cm
TemperatureRange: -20.00 – 50.00 °C
Resolution: ±0.03 °C
Accuracy: ± 0.1 °C (0 °C to 30 °C), ± 0.2 °C (-20 °C to 50 °C)

Communication Specifications

ParameterSpecification
OutputSDI-12 One-wire Serial Interface: DDI communications protocol, SDI-12 communications protocol
RS-485 two-wire-serial-interface (M12 connector only): tensioLINK serial communications protocol, Modbus RTU communications protocol
Data Logger CompatibilityMETER ZL6 data loggers and any data acquisition system capable of 3.8- to 28.0-VDC power and serial interface with SDI-12 and/or RS-485 interface, Modbus RTU or tensioLINK communication

Physical Specifications

ParameterSpecification
DimensionsDiameter: 2.0 cm (0.79 in)
Length: 104.0 cm (40.94 in)
MaterialsShaft: PA66GF30
Sensor Elements: Stainless steel
Operating Temperature RangeMinimum: -30.00 °C
Maximum: 60.00 °C
Cable Length4.5 m (standard)
75 m (maximum cable length using M12 connector and elongation cables)
Connector Types3.5-mm stereo plug connector
4-pin M12 plug connector
NOTE: If a stripped and tinned wire is needed, please contact Customer Support.

Electrical and Timing Characteristics

ParameterSpecification
Supply Voltage (VCC to GND)Minimum: 3.9 VDC continuous
Maximum: 28.0 VDC continuous
Digital Input Voltage (Logic High)Minimum: 1.9 V
Typical: 3.6 V
Maximum: 5.0 V
Digital Input Voltage (Logic Low)Minimum: -0.3 V
Typical: 0.0 V
Maximum: 1.0 V
Digital Output Voltage (Logic High)Typical: 3.6 V continuous
Power Line Slew RateMinimum: 1.0 V/ms
Current Drain (During Measurement)Minimum: 2.0 mA
Typical: 2.5 mA
Maximum: 4.0 mA
Current Drain (While Asleep)Typical: 80 µA
Power Up Time (DDI Serial)Minimum: 210 ms
Maximum: 400 ms
Power Up Time (SDI-12, DDI Disabled)Minimum: 210 ms
Maximum: 400 ms
Power Up Time (RS-485 Ready, DDI Disabled)Minimum: 210 ms
Maximum: 400 ms
Measurement DurationMinimum: 30 ms
Maximum: 240 ms

Other

ParameterSpecification
ComplianceEM ISO/IEC 17050:2010 (CE Mark)
Prop 65 warning
Features

Special Features

01

Multiple Measurement Depths

Features temperature sensors at -5, -10, -20, -30, -50, and -100 cm for detailed soil profile monitoring.
02

Ultra-Robust Construction

Designed for demanding field conditions, providing reliable performance for long-term soil temperature monitoring.
03

High Temperature Accuracy

Provides accurate soil temperature measurements with an impressive accuracy of ±0.1°C.
04

Plug-and-Play Operation

Connects easily with the ZL6 data logger for quick installation and reliable data collection.
Applications

Primary Applications

Climate Research
Ecosystem Research
Environmental Monitoring
water-system
Irrigation Management